Shall comply with the corresponding labeling specification and customer requirement. Shelf Life : 3 years from the date of manufacture.
Batch Nos :
As Per OEM Batch Nos.
Storage condition :
Shall be stored in cool dry place and away from direct light.
Certifications
CE, ISO 9001 : 2015, ISO 13485 : 2016
Quality Standard
ASTM D 3578, EN455, EN 14683 : 2019
Packaging Details
Inner Box :
100 pcs By Weight
Master Carton :
3000 pcs (30 inner boxes)
Physical Dimensions
Length(mm) Min
Size
XS
S
M
L
XL
Length
Min 240mm
Width (mm)
Size
XS
S
M
L
XL
Width (+10)
70+10
80+10
95+10
110+10
120+10
Thickness(mm) Min
Cuff
-
Palm
Min 0.08mm (Single Wall)
Finger
Min 0.08mm (Single Wall)
Physical Properties
Characteristics
Before Ageing
After Ageing
(70 ± 2°C for 166 ± 2 hrs)
Tensile Strength (Mpa) min.
18 mpa Min
14 mpa Min
Ultimate Elongation (%) min.
650% Min
500% Min
Inspection Level (Pre-Shipment)
Freedom from Holes :
Inspection level - I & AQL - 1.5 or AQL - 2.5
Visual defects-Major :
Inspection level - I &
AQL :
1.5 Visual defects-
Minor :
Inspection level –
I & AQL :
2.5
Directions for use
Preparation for use
Ensure selection of gloves with correct size. Below is the correct glove size width:
How to use
Dry hands before donning the gloves.
Take out the product after checking pouch.
Gloves need to be donned carefully; do not apply excessive force to pull the gloves when donning.
Keep the fingernails short and change gloves frequently to avoid tearing issue.
The gloves should be discarded with an appropriate waste disposal container after use according to local disposal regulations.
Cautions for Use
The product is for single use only.
Users should consider the circumstances of use in deciding whether to remove any residual powder on gloves after donning. Powder can be removed by wiping gloves thoroughly with a sterile wet sponge, sterile wet towel or other effective method.
Isolated cases of allergic reactions to latex product or powder have been reported. If you experience a reaction to this product, discontinue use immediately and seek medical help.
Please do not use the gloves after the expire period.
Storage Condition
The atmosphere must always be conducive to the storage of the gloves.
Gloves before opened for use shall be stored in dark, cool and dry place.
Gloves need to avoid area with excessive heat. The storage areas need to be controlled below 40ºC/ 104 ºF.
Gloves need to be stored at the areas with good air ventilation.
Gloves need to be shielded from direct sunlight and fluorescent lighting.
Gloves need to be stored far away from any energy radiating and heat generating equipment.
Expiration Date
The shelf life of the gloves is 3 years from the date of manufacture.
Brand Name : Dastaane Plus
Special Features
Quantity Assurance : 100 pcs packed in each box
AQL 1.5 Assurance : Accepted Quality Limit of 1.5 followed
Weight Assurance : 5.7+0.3gms per pc (medium size)
Shelf Life Assurance: Antioxidant added to increase the shelf life.
Product Information
Material :
Natural Rubber Latex
Colour :
Pale Yellow, the color may vary due to storage time and conditions.
Design :
Straight Fingers, Thumb and Fingers in one plane, Fits either hand (Ambidextrous) Rolled Rim.
Surface Treatment :
No donning powder is used Halogenations and extensive washing in water online.
Powder Content :
≤ 2.0 mg/ dm2 Extractable Protein
Level :
<50 μg/ dm2
Sterile Indicator :
Non Sterile
Labeling :
Shall comply with the corresponding labeling specification and customer requirement. Shelf Life : 3 years from the date of manufacture.
Batch Nos :
As Per OEM Batch Nos.
Storage condition :
Shall be stored in cool dry place and away from direct light.
Certifications
CE, ISO 9001 : 2015, ISO 13485 : 2016
Quality Standard
ASTM D 3578, EN455, EN 14683 : 2019
Packaging Details
Inner Box :
100 pcs By Weight
Master Carton :
3000 pcs (30 inner boxes)
Physical Dimensions
Length(mm) Min
Size
XS
S
M
L
XL
Length
Min 240mm
Width (mm)
Size
XS
S
M
L
XL
Width (+10)
70+10
80+10
95+10
110+10
120+10
Thickness(mm) Min
Cuff
-
Palm
Min 0.08mm (Single Wall)
Finger
Min 0.08mm (Single Wall)
Physical Properties
Characteristics
Before Ageing
After Ageing
(70 ± 2°C for 166 ± 2 hrs)
Tensile Strength (Mpa) min.
18 mpa Min
14 mpa Min
Ultimate Elongation (%) min.
650% Min
500% Min
Stress at 500%
5.5 mpa Max
NA
Inspection Level (Pre-Shipment)
Freedom from Holes :
Inspection level - I & AQL - 1.5 or AQL - 2.5
Visual defects-Major :
Inspection level - I &
AQL :
1.5 Visual defects-
Minor :
Inspection level –
I & AQL :
2.5
Directions for use
Size
XS
S
M
L
XL
Width Range (in mm)
70±10
80+10
95±10
110+10
120+10
Preparation for use
Ensure selection of gloves with correct size. Below is the correct glove size width:
How to use
Dry hands before donning the gloves.
Take out the product after checking the package.
Gloves need to be donned carefully; do not apply excessive force to pull the gloves when donning.
Keep the fingernails short and change gloves frequently to avoid tearing issue.
The gloves should be discarded with an appropriate waste disposal container after use according to local disposal regulations.
Cautions for Use
The product is for single use only.
Isolated cases of allergic reactions to latex product or powder have been reported. If you experience a reaction to this product, discontinue use immediately and seek medical help.
Please do not use the gloves after the expire period.
Storage Condition
The atmosphere must always be conducive to the storage of the gloves.
Gloves before opened for use shall be stored in dark, cool and dry place.
Gloves need to avoid area with excessive heat. The storage areas need to be controlled below 40ºC/ 104 ºF.
Gloves need to be stored at the areas with good air ventilation.
Gloves need to be shielded from direct sunlight and fluorescent lighting.
Gloves need to be stored far away from any energy radiating and heat generating equipment.
Expiration Date
The shelf life of the gloves is 3 years from the date of manufacture.
Brand Name : Dastaane
Special Features
Latex-free, odour-free and powder-free
Can withstand IPA washing (ISO Propyl Alcohol).
Can be used in food industry
Ideal for doctors with latex allergy
Product Information
Material :
Nitrile Rubber, This product does not contain protein found in Natural Rubber Latex
Colour :
Lavender, Blue, Black, Purple, Pink & White.
Design :
Ambidextrous, sterile, beaded cuff and Extra rough (textured) at fingertip surface.
Powder Content :
≤ 2.0 mg/dm2
Sterilization :
Non Sterile
Labeling :
Shall comply with the corresponding labeling specification and customer requirement.
Shelf Life :
3 years from the date of manufacture
Batch Nos :
As Per OEM Batch Nos.
Storage condition :
Shall be stored in cool dry place and away from direct light.
Certifications
CE, ISO 9001 : 2015, ISO 13485 : 2016
Quality Standard
ASTM D 3578, EN455, EN 14683 : 2019
Packaging Details
Inner Box :
100 pcs
Master Carton :
3000 pcs (30 inner boxes)
Physical Dimensions
Length(mm) Min
Size
XS
S
M
L
XL
Length
Min 220mm
Min 230mm
Width (mm)
Size
XS
S
M
L
XL
Width (+10)
70+10
80+10
95+10
110+10
120+10
Palm
Min 0.05mm (Single Wall)
Finger
Min 0.05mm (Single Wall)
Physical Properties
Characteristics
Before Ageing
After Ageing
(70 ± 2°C for 166 ± 2 hrs)
Tensile Strength (Mpa) min.
14 mpa Min
14 mpa Min
Ultimate Elongation (%) min.
500% Min
400% Min
Inspection Level (Pre-Shipment)
Freedom from Holes :
Inspection level - I & AQL - 1.5 or AQL - 2.5
Visual defects-Major :
Inspection level - I &
AQL :
1.5 Visual defects-
Minor :
Inspection level –
I & AQL :
2.5
Directions for use
Preparation for use
Ensure selection of gloves with correct size. Below is the correct glove size width:
Size
XS
S
M
L
XL
Width (+10)
70+10
80+10
95+10
110+10
120+10
How to use
Dry hands before donning the gloves.
Take out the product after checking package.
Gloves need to be donned carefully; do not apply excessive force to pull the gloves when donning.
Keep the fingernails short and change gloves frequently to avoid tearing issue.
The gloves should be discarded with an appropriate waste disposal container after use according to local disposal regulations.
Cautions for Use
The product is for single use only.
Does not contain natural rubber latex.
Please do not use the gloves after the expire period.
Storage Condition
The atmosphere must always be conducive to the storage of the gloves.
Gloves before opened for use shall be stored in dark, cool and dry place.
Gloves need to avoid area with excessive heat. The storage areas need to be controlled below 40ºC/ 104 ºF.
Gloves need to be stored at the areas with good air ventilation.
Gloves need to be shielded from direct sunlight and fluorescent lighting.
Gloves need to be stored far away from any energy radiating and heat generating equipment.
Expiration Date
The shelf life of the gloves is 3 years from the date of manufacture.
Brand Name : Dastaane
Special Features
Finger and palm Mirco Textured design for better grip on handling of surgical instruments
Anatomically shaped curved finger design for comfort fit and long wear ability
Thumb ball design for less stress and better movement of the Thumb
Slightly powdered with absorbable dusting powder to avoid any allergic reaction
Thicker gloves for enhanced safety
Product Information
Material :
Natural Rubber Latex
Colour :
Creamy White
Design :
Hand Specific, Beaded Cuff, Micro rough textured
Powder Content :
< 15mg/dm2
Extractable Protein Level :
< 200 micro gram/dm2
Sterile Indicator :
Non Sterile
Labeling :
Shall comply with the corresponding labeling specification and customer requirement.
Shelf Life :
5 years from the date of manufacture
Batch Nos :
As Per OEM Batch Nos.
Storage condition :
Shall be stored in cool dry place and away from direct light.
Certifications
CE, ISO 9001 : 2015, ISO 13485 : 2016
Quality Standard
ASTM D 3578, EN455, EN 14683 : 2019
Packaging Details
Wallet Wrapper :
1 pair
Pouch :
1 pair
Inner Box :
50 pairs
Master Carton :
500 pairs (10 inner boxes)
Physical Dimensions
Length(mm) Min
Size
5.5
6.0
6.5
7.0
7.5
8.0
8.5
Length
290 ± 10 mm
Width (mm)
Size
5.5
6.0
6.5
7.0
7.5
8.0
8.5
Width (±6)
70
76
83
89
95
102
108
Thickness(mm) Min
Cuff
0.13 Min
Palm
0.15 Min
Finger
0.18 Min
Physical Properties
Characteristics
Before Ageing
After Ageing
(70 ± 2°C for 166 ± 2 hrs)
Tensile Strength (Mpa) min.
24 mpa Min
18 mpa Min
Ultimate Elongation (%) min.
700% Min
550% Min
Stress at 500% Elongation (Mpa) Max.
5.5 mpa
NA
Force at break (N) Min.
12
9
Inspection Level (Pre-Shipment)
ITEM
Inspection Level
AQL
Dimension (Width, Length, Thickness)
S-2
4
Water tightness (Pinhole Test)
G-1
1.5
Force at break and elongation at break (Before and after accelerated ageing)
S-2
4
Force at 300% elongation (Before accelerated ageing)
S-2
4
Directions for use
Preparation for use
Ensure selection of gloves with correct size. Below is the correct glove size width:
How to use
Dry hands before donning the gloves.
Take out the product after checking package.
Gloves need to be donned carefully; do not apply excessive force to pull the gloves when donning.
Keep the fingernails short and change gloves frequently to avoid tearing issue.
The gloves should be discarded with an appropriate waste disposal container after use according to local disposal regulations.
Cautions for Use
The product is for single use only.
Sterility guaranteed until package is opened or damaged.
Users should consider the circumstances of use in deciding whether to remove any residual powder on gloves after donning. Powder can be removed by wiping gloves thoroughly with a sterile wet sponge, sterile wet towel or other effective method.
Isolated cases of allergic reactions to latex product or powder have been reported. If you experience a reaction to this product, discontinue use immediately and seek medical help
Please do not use the gloves after the expire period.
Storage Condition
The atmosphere must always be conducive to the storage of the gloves.
Gloves before opened for use shall be stored in dark, cool and dry place.
Gloves need to avoid area with excessive heat. The storage areas need to be controlled below 40ºC/ 104 ºF.
Gloves need to be stored at the areas with good air ventilation.
Gloves need to be shielded from direct sunlight and fluorescent lighting.
Gloves need to be stored far away from any energy radiating and heat generating equipment.
Expiration Date
The shelf life of the gloves is 5 years from the date of manufacture.
Brand Name : Dastaane
Special Features
Finger and palm Mirco Textured design for better grip on handling of surgical instruments
Anatomically shaped curved finger design for comfort fit and long wear ability
Thumb ball design for less stress and better movement of the Thumb
Slightly powdered with absorbable dusting powder to avoid any allergic reaction
Thicker gloves for enhanced safety
Product Information
Material :
Natural Rubber Latex
Colour :
Creamy White
Design :
Hand Specific, Beaded Cuff, Micro rough textured
Powder Content :
< 15mg/dm2
Extractable Protein Level :
< 200 micro gram/dm2
Sterile Indicator :
Non Sterile
Labeling :
Shall comply with the corresponding labeling specification and customer requirement.
Shelf Life :
5 years from the date of manufacture
Batch Nos :
As Per OEM Batch Nos.
Storage condition :
Shall be stored in cool dry place and away from direct light.
Certifications
CE, ISO 9001 : 2015, ISO 13485 : 2016
Quality Standard
ASTM D 3578, EN455, EN 14683 : 2019
Packaging Details
Wallet Wrapper :
1 pair
Pouch :
1 pair
Inner Box :
50 pairs
Master Carton :
500 pairs (10 inner boxes)
Physical Dimensions
Length(mm) Min
Size
5.5
6.0
6.5
7.0
7.5
8.0
8.5
Length
290 ± 10 mm
Width (mm)
Size
5.5
6.0
6.5
7.0
7.5
8.0
8.5
Width (±6)
70
76
83
89
95
102
108
Thickness(mm) Min
Cuff
0.13 Min
Palm
0.15 Min
Finger
0.18 Min
Physical Properties
Characteristics
Before Ageing
After Ageing
(70 ± 2°C for 166 ± 2 hrs)
Tensile Strength (Mpa) min.
24 mpa Min
18 mpa Min
Ultimate Elongation (%) min.
700% Min
550% Min
Stress at 500% Elongation (Mpa) Max.
5.5 mpa
NA
Force at break (N) Min.
12
9
Inspection Level (Pre-Shipment)
ITEM
Inspection Level
AQL
Dimension (Width, Length, Thickness)
S-2
4
Water tightness (Pinhole Test)
G-1
1.5
Force at break and elongation at break (Before and after accelerated ageing)
S-2
4
Force at 300% elongation (Before accelerated ageing)
S-2
4
Directions for use
Preparation for use
Ensure selection of gloves with correct size. Below is the correct glove size width:
How to use
Dry hands before donning the gloves.
Take out the product after checking package.
Gloves need to be donned carefully; do not apply excessive force to pull the gloves when donning.
Keep the fingernails short and change gloves frequently to avoid tearing issue.
The gloves should be discarded with an appropriate waste disposal container after use according to local disposal regulations.
Cautions for Use
The product is for single use only.
Sterility guaranteed until package is opened or damaged.
Users should consider the circumstances of use in deciding whether to remove any residual powder on gloves after donning. Powder can be removed by wiping gloves thoroughly with a sterile wet sponge, sterile wet towel or other effective method.
Isolated cases of allergic reactions to latex product or powder have been reported. If you experience a reaction to this product, discontinue use immediately and seek medical help
Please do not use the gloves after the expire period.
Storage Condition
The atmosphere must always be conducive to the storage of the gloves.
Gloves before opened for use shall be stored in dark, cool and dry place.
Gloves need to avoid area with excessive heat. The storage areas need to be controlled below 40ºC/ 104 ºF.
Gloves need to be stored at the areas with good air ventilation.
Gloves need to be shielded from direct sunlight and fluorescent lighting.
Gloves need to be stored far away from any energy radiating and heat generating equipment.
Expiration Date
The shelf life of the gloves is 5 years from the date of manufacture.
Brand Name : Dastaane
Special Features
Finger and palm Mirco Textured design for better grip on handling of surgical instruments
Anatomically shaped curved finger design for comfort fit and long wear ability
Thumb ball design for less stress and better movement of the Thumb
Slightly powdered with absorbable dusting powder to avoid any allergic reaction
Shall comply with the corresponding labeling specification and customer requirement.
Shelf Life :
3 years from the date of manufacture
Batch Nos :
As Per OEM Batch Nos.
Storage condition :
Shall be stored in cool dry place and away from direct light.
Certifications
CE, ISO 9001 : 2015, ISO 13485 : 2016
Quality Standard
ASTM D 3578, EN455, EN 14683 : 2019
Packaging Details
Wallet Wrapper :
1 pair
Pouch :
1 pair
Inner Box :
50 pairs
Master Carton :
500 pairs (10 inner boxes)
Physical Dimensions
Length(mm) Min
Size
5.5
6.0
6.5
7.0
7.5
8.0
8.5
Length
300 ± 10 mm
Width (mm)
Size
5.5
6.0
6.5
7.0
7.5
8.0
8.5
Width (±6)
70
76
83
89
95
102
108
Thickness(mm) Min
Cuff
0.13 Min
Palm
0.15 Min
Finger
0.19 Min
Physical Properties
Characteristics
Before Ageing
After Ageing
(70 ± 2°C for166 ± 2 hrs)
Tensile Strength (Mpa) min.
24 mpa Min
18 mpa Min
Ultimate Elongation (%) min.
700% Min
550% Min
Stress at 500% Elongation (Mpa) Max.
5.5 mpa
NA
Force at break (N) Min.
12
9
Inspection Level (Pre-Shipment)
ITEM
Inspection Level
AQL
Dimension (Width, Length, Thickness)
S-2
4
Water tightness (Pinhole Test)
G-1
1.5
Force at break and elongation at break (Before and after accelerated ageing)
S-2
4
Force at 300% elongation (Before accelerated ageing)
S-2
4
Directions for use
Size
5.5
6.0
6.5
7.0
7.5
8.0
8.5
9.0
Width Range (mm) (+6)
70
76
83
89
95
102
108
114
Preparation for use
Ensure selection of gloves with correct size. Below is the correct glove size width:
How to use
Dry hands before donning the gloves.
Take out the product after checking pouch.
Gloves need to be donned carefully; do not apply excessive force to pull the gloves when donning.
Keep the fingernails short and change gloves frequently to avoid tearing issue.
The gloves should be discarded with an appropriate waste disposal container after use according to local disposal regulations.
Cautions for Use
The product is for single use only.
Sterility guaranteed until package is opened or damaged.
Isolated cases of allergic reactions to latex product or powder have been reported. If you experience a reaction to this product, discontinue use immediately and seek medical help
Please do not use the gloves after the expire period.
Storage Condition
The atmosphere must always be conducive to the storage of the gloves.
Gloves before opened for use shall be stored in dark, cool and dry place.
Gloves need to avoid area with excessive heat. The storage areas need to be controlled below 40ºC/ 104 ºF.
Gloves need to be stored at the areas with good air ventilation.
Gloves need to be shielded from direct sunlight and fluorescent lighting.
Gloves need to be stored far away from any energy radiating and heat generating equipment.
Expiration Date
The shelf life of the gloves is 3 years from the date of manufacture.
Brand Name : Defender
Description
3 Ply Disposable Face Mask is designed to limit the spread of germs and promote proper hygiene. The practical construction of the 3 ply pollution mask ensures maximum comfort and can be worn for extended hours even during hot and humid conditions. The face mask has three fabric layers and the three-layer filtration offers cleaner air to breathe and prevents transmission of foreign bodies. It comes with super soft elastic ear loops making it easy and comfortable to wear. This face mask is ideal for day to day activities as well as for doctors, surgeons, dentists, dental assistants, nurses, landscapers, contractors, plumbers, exterminators, nail technicians, etc. 3-Ply masks: Disposable & affordable options that are apt for Protection.
Product Specifications
Mask Type :
3 PLY
Material Layer 1 :
Non woven
Material Layer 2 :
Meltblown Filter
Material Layer 3 :
Non woven
Loop :
Elastic streachable ear loop
Manufacturer :
DHealth Safe India Private Limited, Mysore, Karnataka - 570008
Country of Origin :
India
Features
Made using soft fabric to provide maximum comfort
Triple layer construction for maximum safety
Unisex mask, can be used by men & women
Features elastic ear loops to ensure perfect fit
Foldable and easy to carry
Can be used at home, in office, during traveling or walking
Offers powerful protection against air pollution
Protects from dust, germs and air borne contaminants
How to use Disposable Face Mask with Elastic Ear Loops - Seniority
How to put on a 3 Ply Face Mask?
Clean your hands with soap and water or hand sanitizer before touching the mask
Check for defects in the face mask, such as tears or broken loops
Determine which side of the mask is the top and position it accordingly on your face
Hold the mask by the ear loops and place a loop around each ear
Pull the bottom of the 3 layer mask over your mouth and chin and ensure that the mask fits properly
Don’t touch the mask once in position
How to remove a 3 Ply Face Mask?
Before you take off the 3 layer mask, wash your hands well or use hand sanitizer
Avoid touching the front of the mask, as it could be contaminated. Only touch the ear loops
Unhook both ear loops and gently lift and remove the mask
After removing, throw the mask in the dustbin and wash your hands thoroughly or use hand sanitizer
Brand Name : Defender
Description
Demand has soared for respiratory protection products. During the coronavirus pandemic, masks, once relegated to specific professions, are quickly becoming commonplace. 5 Ply Disposable Face Mask is designed to limit the spread of germs and promote proper hygiene. The practical construction of the 5 Ply N95 pollution mask ensures maximum comfort and can be worn for extended hours even during hot and humid conditions. The face mask has 5 layers and the 5-layer filtration offers cleaner air to breathe and prevents transmission of foreign bodies. It comes with super soft elastic ear loops making it easy and comfortable to wear. This face mask is ideal for day to day activities as well as for doctors, surgeons, dentists, dental assistants, nurses, landscapers, contractors, plumbers, exterminators, nail technicians, etc.
Product Specifications
Mask Type :
5 PLY N95/FFP2 Respirator
Fiteration :
PM2.5 filtration rate ≥ 95%
Material Layer 1 :
Non Woven Polyproplene Fabric
Material Layer 2 :
Meltblown Filter
Material Layer 3 :
Meltblown Filter
Material Layer 4 :
Filter Sponge
Material Layer 5 :
Ultra Soft Non Woven Fabric
Loop :
Elastic soft stretchable ear loop
Nose Clip :
Flexible & Adjustable nose clip
Manufacturer :
DHealth Safe India Private Limited, Mysore, Karnataka - 570008
Country of Origin :
India
Certifications
CE, ISO 9001 : 2015, ISO 13485 : 2016, EN 14683 : 2019, EN 149 : 2001 + A1:2009
Features
Made using soft fabric to provide maximum comfort
Triple layer construction for maximum safety
Unisex mask, can be used by men & women
Features elastic ear loops to ensure perfect fit
Foldable and easy to carry
Can be used at home, in office, during traveling or walking
Offers powerful protection against air pollution
Protects from dust, germs and air borne contaminants
How to use Disposable Face Mask with Elastic Ear Loops - Seniority
How to put on a 5 Ply N95 Face Mask?
Clean your hands with soap and water or hand sanitizer before touching the mask
Check for defects in the face mask, such as tears or broken loops
Determine which side of the mask is the top and position it accordingly on your face
Hold the mask by the ear loops and place a loop around each ear
Pull the bottom of the 3 layer mask over your mouth and chin and ensure that the mask fits properly
Don’t touch the mask once in position
How to remove a 5 Ply N95 Face Mask?
Before you take off the 3 layer mask, wash your hands well or use hand sanitizer
Avoid touching the front of the mask, as it could be contaminated. Only touch the ear loops
Unhook both ear loops and gently lift and remove the mask
After removing, throw the mask in the dustbin and wash your hands thoroughly or use hand sanitizer
We are offering our customers an excellent quality range of Bouffant Cap. This cap is very light in weight and comfortable to wear. By keeping track with the latest market developments, we are offering high quality Head Cap which protects the head from heat and moisture. These head caps are available in varied sizes & customized options as per the needs of customers. Offered head caps are generally used in various sectors like hospitals, hotels and places where hair fall contamination is major problem. Customers can avail these head caps from us in quality packaging which maintain its hygiene.
Features
Ultrasonic Sealing
Unisex mask, can be used by men & women
Avoids escape of hair, dandruff and micro-organisms during process
Secure elastic
Product Details:
Material :
Non Woven
Size :
18 & 21 INCH
Color :
Blue Green White Black Yellow
Certifications
CE, ISO 9001 : 2015, ISO 13485 : 2016, EN 14683 : 2019, EN 149 : 2001 + A1:2009
Usage/Application :
Pharmaceuticals
Hospitals
Food industry
Research institutes
Laboratories
Agro chemicals
Chemicals
Paint industry
Catering industry
Brand : Dharma
Thickness : 80 Micron
Product Details:
Material :
Non Woven
Color :
Green, Blue, etc.
Usage/Application :
Clinic, Hospital , etc.
Brand :
Dharma
Thickness :
80 Micron
We are the leading manufacturer of High Quality Surgical cap and Disposable Surgical Cap. Offered surgical caps are extensively in demand in different medical sectors and hence appreciated due to their tear strength and high sterile standards. These surgical caps are mostly used by the medical practitioners and doctors during surgeries & operations. We ensure to provide these surgical caps to our customers at most genuine rates.
Features
Provide comfort, dryness to the wearer
Breath ability and trap perspiration
Light in weight and comfortable to wear
Prevent from skin irritation
Easy adjustable elastic
Prevent from bacteria
Excellent Durability and quality
Competitive price advantage
Different colors available
Packaging can be customized according to client’s requirement
Product Details:
Quantity per pack :
25
Material :
Non Woven
Color :
Blue
Brand :
Dharma
Country of Origin :
Made in India
Thickness :
80 Micron
Our valuable clients can avail from us an exclusive collection of Plastic Shoe Cover. Offered cover is designed by our experienced professionals using high grade fabric and other requisite materials in accordance with the needs of various industries. This range is stringently tested on various parameters keeping in mind the defined industry norms. Available in different specifications, this cover can also be custom tailored as per the needs of the clients.
Features
High strength
Easy to use
Fine finish
Tear resistance
Properties
Available in PP/PE and Non-woven material
High Quality with a competitive price
Water and dust proof
Different Colors available
Packaging can be customized according to client’s requirement
Applications
Pharmaceutical manufacturing facility
Hospitals
Food areas
Inspection industries
Bio-engineering
Electromechanical and chemical industries
Sample villas
Home and apartments
Office
We supply all types of syringes and needles from reputed companies like Hindustan Syringes & Medical Devices Ltd (HMD) and Nihal Healthcare, at a much competitive and affordable rate with best discounts to hospitals and distributors. Please call connect with us for best rates.
We supply absorbable or nonabsorbable sutures from reputed companies like Johnson and Johnson’s Ethicon Sutures and of Suture India, at a much competitive and affordable rate with best discounts to hospitals and distributors. Please call connect with us for best rates.